[GUEST ACCESS MODE: Data is scrambled or limited to provide examples. Make requests using your API key to unlock full data. Check https://lunarcrush.ai/auth for authentication information.]

@thefreondon Avatar @thefreondon TheFreonDon

TheFreonDon posts on TikTok about $6367t, mitsubishi, $8306t, $8058t the most. They currently have XXXXX followers and X posts still getting attention that total XX engagements in the last XX hours.

Engagements: XX #

Engagements Line Chart

Mentions: X #

Mentions Line Chart

Followers: XXXXX #

Followers Line Chart

CreatorRank: undefined #

CreatorRank Line Chart

Social Influence

Social category influence automotive brands technology brands

Social topic influence $6367t, mitsubishi, $8306t, $8058t, $6503t, pve, lg, meter, $003550ks

Top Social Posts

Top posts by engagements in the last XX hours

"Mitsubishi Electric VRF DC Voltage Tracing Overview. When troubleshooting Mitsubishi Electric VRF systems DC voltage can be traced through the following key components: X. Noise Filter Board Initial DC voltage path begins here after AC input passes through the noise filter and rectification stage. X. Capacitor The smoothing capacitor stabilizes the DC bus voltage. X. Inverter Board Converts DC to a variable frequency AC for compressor and fan operation. X. Control PCB Handles logic and system control. X. M-Net PCB Manages communication between indoor and outdoor units via M-Net protocol. This"
TikTok Link 2025-08-02T03:57Z 2166 followers, 21.9K engagements

"A while back I worked on a Daikin VRV Emerion system that required PVE oil. This is just one of several ways to add lubrication oilin this case PVEto a running VRV/VRF system. Im sure there are other methods out there using different tools or pumps. We made sure to follow the proper procedures to avoid introducing moisture into the system. For this job I used the Yellow Jacket Max-Flow Deluxe Oil Pump for the first time. Most of the time Ive added oil during compressor replacements when the system has no refrigerant present so this was a different experience. Everything went smoothly and"
TikTok Link 2025-08-03T00:56Z 2167 followers, 11.4K engagements

"Today I was performing a leak search on this Daikin VRV Life system. Its important to understand that these systems have a vacuum mode that should be activated when performing recovery pulling a vacuum or pressure testing. Why it matters: Vacuum mode ensures the system is fully open both the condenser and all indoor units. It forces all solenoids and EEVs to open completely allowing you to work on the entire refrigerant circuit. For this to work: All indoor and outdoor units must be energized Communication must be normal with no error codes present Where to find it: This setting is adjusted"
TikTok Link 2025-08-09T00:24Z 2166 followers, 19.7K engagements

"System Information: Unit Model: ARUM241DTE5 Type: XXX V large-frame LG Multi V X outdoor unit Step-by-Step Inverter Board Replacement Guide: X. Safety First Power Off & Lockout: De-energize the outdoor unit and apply lockout/tagout procedures wait 10-15 mins after shutdown. Discharge DC Link: Using a meter verify zero voltage across P and N terminals before proceeding. X. Access the Control Section Remove the control box cover. Carefully detach and swing out the front control panel assembly to access the rear section disconnecting harnesses as necessary. X. Remove the Inverter Board"
TikTok Link 2025-09-07T00:09Z 2166 followers, 16.4K engagements